Internal Electric Blinds - High Level Configuration

High level configuration should only be carried out if the product, isn’t stopping to its chosen position.

Step 1

Ensure the blind is in the fully UP position

Move bind manually if not.

Step 2

Disconnect the power from the motor for 30 seconds.

Turn off the mains supply to the window or KUX.

Step 3

Re-connect the power to the motor.

Connect mains power to the window or KUX.

Step 4

Carry out the following process depending on the remote control.

Go to Step 5-6

Go to Step 7-8

Go to Step 9-10

Go to Step 11-12


Step 5

Press the STOP button, immediately followed by the DOWN button within 3 seconds.

Step 6

Once the blind has reached the bottom of the window, then operate the blind as normal.


Step 7

Press the STOP button, immediately followed by the DOWN button within 3 seconds.

Step 8

Once the blind has reached the bottom of the window, then operate the blind as normal.


Step 9

 Select the blind on the remote, and press the STOP icon, immediately followed by the CLOSE icon.

Step 10

Once the blind has reached the bottom of the window, then operate the blind as normal.


Step 11

Select the blind on the remote, and press the STOP button, immediately followed by the DOWN button.

Step 12

Once the blind has reached the bottom of the window, then operate the blind as normal.